E-201Feature · Electrical & plumbing
Plan the wiring and plumbing on the same drawing as your walls
Place switches, sockets, fans, lights and fixtures on your plan, or let Auto design do it. Conduit and pipes route through the walls, wire is sized for 230 V circuits, and every metre and fitting lands in the bill of quantities.
- Conduit · 557 m
- Cold water · 28 m
- Waste (grey) · 15 m
- Soil (black) · 9 m
The ground floor of the sample house after Auto design
Wiredon paper
Electrical and plumbing layouts are often a separate drawing, marked up by the electrician on site and counted by the contractor later. Nobody sees the cable or pipe until the bill arrives. Here the points sit on the same plan as the walls, so the runs, the board and the quantities come from one drawing.
E-201.2How it works
From the first wall to the finished layout
01
Place the points
Put switchboards, 6 A and 16 A sockets, lights, fans, AC points and exhaust fans where they go, and taps, showers, basins and WCs in the wet rooms. Or let Auto design place them room by room from each room's use.
02
Runs route through the walls
Conduit is chased through the walls or cast in the slab, and its route is drawn on the plan with a side view of every run. Supply pipes are chased into the walls; drainage is laid at a fall to the stack.
03
Circuits and the board
Loads are dealt onto circuits by the project's wiring rules, a board goes on each storey and the main board feeds the others with a sub-main up a shared riser. Wire is sized per circuit for 230 V, and overloaded runs are flagged before anything is built.
- MCB, SP, C-curve44
- 16A Power Socket34
- 6A Socket27
- Switch25
- Wall light22
- Spot light13
- Tube light10
04
Every metre into the BOQ
Cable by size, conduit by diameter, pipe by system and every fitting become priced lines in the bill of quantities, with installation labour per point and per metre the way Indian contractors quote it.
Services, from the BOQ
Electrical · 100 lines₹6,50,177
Plumbing · 53 lines₹1,92,454
E-201.3What you get
- Boards and circuits
- A distribution board per storey, MCBs and an RCCB, loads dealt onto circuits by rules you can change.
- Switch-to-light wiring
- Every button knows the lights or fan it switches, so the wiring follows when you move either.
- Concealed conduit
- Routed through wall chases or the slab, with a side view of each run and its length.
- Load checks
- Wire sized for 230 V circuits, with overloaded runs and boards flagged.
- Supply and drainage
- Cold and hot water, waste and soil lines with fixture units per bathroom and kitchen.
- Between storeys
- Sub-mains up a shared riser, marked ▲ ▼ on the plan; draw a cable that carries on to the floor above, below or underground.
- Switch together
- Select lights, fans or sockets and put them on a new switch, or an existing one; test every switch in 3D before it's built.
- Layouts to print
- Electrical and plumbing sheets for every storey in the PDF drawing set, at a true scale.
- Smart home ready
- Link lights and switches to Home Assistant entities and export the house as a live 3D dashboard.
E-201.4From the sample house
The sample house, wired and plumbed
After Auto design the Two-storey sample house has 44 circuits, 3,338 m of cable in 557 m of concealed conduit, and 52 m of pipe. Every item below is a line in its bill of quantities.
Electrical items
- MCB, SP, C-curve44
- 16A Power Socket34
- 6A Socket27
- Switch25
- Wall light22
- Spot light13
- Tube light10
- Ceiling Fan9
- Fan regulator7
- AC Indoor Unit6
- Exhaust Fan5
- Modular plate + box, 1M4
- Modular plate + box, 2M4
- Modular plate + box, 4M4
- Ceiling light2
- Distribution Board2
- Modular plate + box, 3M2
- RCCB, DP, 30 mA2
- Inverter / UPS1
- Modular plate + box, 6M1
Plumbing items
- Bend 87.5°36
- Elbow 90°28
- Wash Basin5
- Cold Water Riser4
- Floor Drain4
- Shower4
- Soil / Vent Stack4
- WC4
- Kitchen Sink2
- Washing Machine1
- Cold water pipe28 m
- Waste (grey) pipe15 m
- Soil (black) pipe9 m
E-201.6 / The symbols
What the marks on the layout mean
Switchboard
A modular plate of switches and sockets; its buttons are wired to the lights and fans they control.
Socket
6 A for lamps and chargers, 16 A for the geyser, AC, oven and washing machine.
Light
Ceiling, wall, spot, tube and profile lights, placed for an even level in each room.
Fan
A ceiling fan and its regulator, on the same circuit as the room's lights.
Distribution board
The board each storey feeds from, with an MCB per circuit and an RCCB.
Water supply
Cold and hot CPVC runs from the riser to every tap, shower and WC.
Drainage
Waste and soil lines in uPVC SWR, laid at a fall to the stack.
Floor drain
In every bathroom and wet area, connected to the waste line.
E-201.5Compared with how it's usually done
Points
- Electrician's markup
- Pencil on a print
- Generic CAD
- Blocks on a layer
- Nuvie Planner
- Points that know their room and circuit
Runs
- Electrician's markup
- Decided on site
- Generic CAD
- Drawn by hand
- Nuvie Planner
- Routed through the walls automatically
Wire sizes
- Electrician's markup
- Rule of thumb
- Generic CAD
- Calculated separately
- Nuvie Planner
- Sized per circuit for 230 V
Quantities
- Electrician's markup
- Counted after
- Generic CAD
- Counted by hand
- Nuvie Planner
- Counted from the plan into the BOQ
E-201.9FAQ
Questions people ask
How many electrical points does a house need?
It depends on the rooms and how they're used. As a reference, the sample house - 5 bedrooms over 3,056 sq ft - comes to 61 sockets and 25 switches after Auto design. Your own plan counts its own.
Can I mark circuits and the distribution board?
Yes. Place the board yourself or let Auto design put one on each storey, then assign loads to circuits by hand or by the project's wiring rules.
Does it size the wire?
Yes. Each circuit's cable is sized for its connected load on 230 V, and overloaded runs are flagged.
Can my electrician or plumber get a printable layout?
Yes. The PDF drawing set has an electrical and a plumbing sheet for every storey at a true scale, and the quantities export as CSV.
Are the services included in the estimate?
Yes. Cable, conduit, pipe, fittings and fixtures are priced lines in the bill of quantities, with labour per point and per metre.
Does it wire a house with more than one storey?
Yes. Each storey gets its own board, and the main board feeds them with a 6 mm² sub-main up a shared riser. The riser shows on the plan, in 3D, in the schedule and in the quantities.
Can I use it to set up a smart home?
Yes. Link each light, fan or switch button to its Home Assistant entity and export: Home Assistant gets your rooms as areas and a 3D card with every device live.
Is the wiring placed automatically?
If you want it to be. Auto design places points, plumbing and circuits for a room, a storey or the whole house, and leaves anything you placed by hand alone.
Start with the room you're standing in.
Draw one wall and the rest follows. Your first plan takes minutes, and it's free.