Plan the wiring and plumbing on the same drawing as your walls

Place switches, sockets, fans, lights and fixtures on your plan, or let Auto design do it. Conduit and pipes route through the walls, wire is sized for 230 V circuits, and every metre and fitting lands in the bill of quantities.

Ground Floor: electrical and plumbing runs
  • Conduit · 557 m
  • Cold water · 28 m
  • Waste (grey) · 15 m
  • Soil (black) · 9 m

The ground floor of the sample house after Auto design

Wiredon paper

Electrical and plumbing layouts are often a separate drawing, marked up by the electrician on site and counted by the contractor later. Nobody sees the cable or pipe until the bill arrives. Here the points sit on the same plan as the walls, so the runs, the board and the quantities come from one drawing.

E-201.2How it works

From the first wall to the finished layout

  1. 01

    Place the points

    Put switchboards, 6 A and 16 A sockets, lights, fans, AC points and exhaust fans where they go, and taps, showers, basins and WCs in the wet rooms. Or let Auto design place them room by room from each room's use.

    Points on the plan
  2. 02

    Runs route through the walls

    Conduit is chased through the walls or cast in the slab, and its route is drawn on the plan with a side view of every run. Supply pipes are chased into the walls; drainage is laid at a fall to the stack.

    Conduit and pipe runs
  3. 03

    Circuits and the board

    Loads are dealt onto circuits by the project's wiring rules, a board goes on each storey and the main board feeds the others with a sub-main up a shared riser. Wire is sized per circuit for 230 V, and overloaded runs are flagged before anything is built.

    • MCB, SP, C-curve44
    • 16A Power Socket34
    • 6A Socket27
    • Switch25
    • Wall light22
    • Spot light13
    • Tube light10
  4. 04

    Every metre into the BOQ

    Cable by size, conduit by diameter, pipe by system and every fitting become priced lines in the bill of quantities, with installation labour per point and per metre the way Indian contractors quote it.

    Services, from the BOQ

    Electrical · 100 lines₹6,50,177

    Plumbing · 53 lines₹1,92,454

E-201.3What you get

Boards and circuits
A distribution board per storey, MCBs and an RCCB, loads dealt onto circuits by rules you can change.
Switch-to-light wiring
Every button knows the lights or fan it switches, so the wiring follows when you move either.
Concealed conduit
Routed through wall chases or the slab, with a side view of each run and its length.
Load checks
Wire sized for 230 V circuits, with overloaded runs and boards flagged.
Supply and drainage
Cold and hot water, waste and soil lines with fixture units per bathroom and kitchen.
Between storeys
Sub-mains up a shared riser, marked ▲ ▼ on the plan; draw a cable that carries on to the floor above, below or underground.
Switch together
Select lights, fans or sockets and put them on a new switch, or an existing one; test every switch in 3D before it's built.
Layouts to print
Electrical and plumbing sheets for every storey in the PDF drawing set, at a true scale.
Smart home ready
Link lights and switches to Home Assistant entities and export the house as a live 3D dashboard.

E-201.4From the sample house

The sample house, wired and plumbed

After Auto design the Two-storey sample house has 44 circuits, 3,338 m of cable in 557 m of concealed conduit, and 52 m of pipe. Every item below is a line in its bill of quantities.

Electrical items

  • MCB, SP, C-curve44
  • 16A Power Socket34
  • 6A Socket27
  • Switch25
  • Wall light22
  • Spot light13
  • Tube light10
  • Ceiling Fan9
  • Fan regulator7
  • AC Indoor Unit6
  • Exhaust Fan5
  • Modular plate + box, 1M4
  • Modular plate + box, 2M4
  • Modular plate + box, 4M4
  • Ceiling light2
  • Distribution Board2
  • Modular plate + box, 3M2
  • RCCB, DP, 30 mA2
  • Inverter / UPS1
  • Modular plate + box, 6M1

Plumbing items

  • Bend 87.5°36
  • Elbow 90°28
  • Wash Basin5
  • Cold Water Riser4
  • Floor Drain4
  • Shower4
  • Soil / Vent Stack4
  • WC4
  • Kitchen Sink2
  • Washing Machine1
  • Cold water pipe28 m
  • Waste (grey) pipe15 m
  • Soil (black) pipe9 m

E-201.6 / The symbols

What the marks on the layout mean

  • Switchboard

    A modular plate of switches and sockets; its buttons are wired to the lights and fans they control.

  • Socket

    6 A for lamps and chargers, 16 A for the geyser, AC, oven and washing machine.

  • Light

    Ceiling, wall, spot, tube and profile lights, placed for an even level in each room.

  • Fan

    A ceiling fan and its regulator, on the same circuit as the room's lights.

  • Distribution board

    The board each storey feeds from, with an MCB per circuit and an RCCB.

  • Water supply

    Cold and hot CPVC runs from the riser to every tap, shower and WC.

  • Drainage

    Waste and soil lines in uPVC SWR, laid at a fall to the stack.

  • Floor drain

    In every bathroom and wet area, connected to the waste line.

E-201.5Compared with how it's usually done

  • Points

    Electrician's markup
    Pencil on a print
    Generic CAD
    Blocks on a layer
    Nuvie Planner
    Points that know their room and circuit
  • Runs

    Electrician's markup
    Decided on site
    Generic CAD
    Drawn by hand
    Nuvie Planner
    Routed through the walls automatically
  • Wire sizes

    Electrician's markup
    Rule of thumb
    Generic CAD
    Calculated separately
    Nuvie Planner
    Sized per circuit for 230 V
  • Quantities

    Electrician's markup
    Counted after
    Generic CAD
    Counted by hand
    Nuvie Planner
    Counted from the plan into the BOQ

E-201.9FAQ

Questions people ask

How many electrical points does a house need?

It depends on the rooms and how they're used. As a reference, the sample house - 5 bedrooms over 3,056 sq ft - comes to 61 sockets and 25 switches after Auto design. Your own plan counts its own.

Can I mark circuits and the distribution board?

Yes. Place the board yourself or let Auto design put one on each storey, then assign loads to circuits by hand or by the project's wiring rules.

Does it size the wire?

Yes. Each circuit's cable is sized for its connected load on 230 V, and overloaded runs are flagged.

Can my electrician or plumber get a printable layout?

Yes. The PDF drawing set has an electrical and a plumbing sheet for every storey at a true scale, and the quantities export as CSV.

Are the services included in the estimate?

Yes. Cable, conduit, pipe, fittings and fixtures are priced lines in the bill of quantities, with labour per point and per metre.

Does it wire a house with more than one storey?

Yes. Each storey gets its own board, and the main board feeds them with a 6 mm² sub-main up a shared riser. The riser shows on the plan, in 3D, in the schedule and in the quantities.

Can I use it to set up a smart home?

Yes. Link each light, fan or switch button to its Home Assistant entity and export: Home Assistant gets your rooms as areas and a 3D card with every device live.

Is the wiring placed automatically?

If you want it to be. Auto design places points, plumbing and circuits for a room, a storey or the whole house, and leaves anything you placed by hand alone.

Start with the room you're standing in.

Draw one wall and the rest follows. Your first plan takes minutes, and it's free.